Het Facq-centrum in Merelbeke omvat in elke ruimte systemen die toelaten om het gebouw veilig te ontroken en mensen te evacueren.
Het Facq-centrum in Merelbeke omvat in elke ruimte systemen die toelaten om het gebouw veilig te ontroken en mensen te evacueren.

Facq moved into its new Flanders Headoffice at the end of last year. With a total floor area of 30,000 square metres, it is also the Belgian specialist in sanitaryware and heating’s largest centre.

The striking building alongside the E40 in Merelbeke stands out for its 300-metre-long, 16-metre-high façade, featuring around 8,000 square metres of glazing. Naturally, fire safety also received considerable attention. Kingspan Light + Air Belgium’s specialists were brought in during the design phase to help develop the smoke and heat exhaust concept. The specialist installed smoke vents with night cooling in the warehouse, Sanicenter, showroom and offices, along with a vast glazed roof structure in the atrium.

The new Facq centre comprises a distribution centre, Collect & Go service, Contact Center, showroom, Sanicenter and offices. It is the place to be for professionals in sanitaryware and heating, as well as for members of the public looking for inspiration and innovative solutions for their new-build and renovation projects. Facq’s management focused not only on an inviting façade and a clear, functional layout, but also on fire safety. As a trusted partner for integrating daylight, natural ventilation and smoke and heat exhaust solutions into facilities, Kingspan Light + Air Belgium was also brought in for this project during the study phase, almost two years before construction began. The architect and client asked the company to help define the smoke and heat exhaust concept. The specialist integrated several rooflights and Kingspan Optima smoke and heat exhaust systems with ventilation modules in the warehouse, showroom, Sanicenter and offices in Merelbeke. For the atrium, Kingspan Light + Air’s experts designed a glazed roof structure fitted with smoke and heat exhaust windows and smoke curtains. This allows the spaces to be safely cleared of smoke in the event of a fire while occupants are evacuated.

For the atrium, Kingspan’s experts designed and installed an impressive 110-metre-long glazed rooflight (pitched roof), the centrepiece of the installations.

Rooflights with smoke vents and ventilation modules

Kingspan Light + Air engineered and installed the glass and polycarbonate rooflights for the various spaces. These daylight solutions use the company’s own Brakel BA-4 glazing bar system, which clamps the panes on all four sides. “Kingspan Optima smoke and heat exhaust ventilators were also installed in the warehouse, Sanicenter and showroom. These louvre ventilators are 100 per cent thermally broken and highly insulated, preventing condensation and ensuring unrivalled air and water tightness. All the smoke vents are also fitted with a ventilation module. This can open the smoke vents to a 5-degree ventilation position, allowing the building and indoor air to be cooled and ventilated naturally at night, while keeping out the rain,” explains engineering manager Cedrik Van Cannegem. “We also integrated a smoke and heat exhaust system and smoke curtains in the offices, while Inova ventilation windows in the façade provide controlled mechanical ventilation. External solar shading prevents overheating on hot, sunny days.”

Complex glazed roof structure in the atrium

Designing a solution for the atrium proved particularly challenging. Belgian fire safety regulations assume that the different storeys of a building are separated from one another by fire-resistant barriers. An atrium, however, is by definition open and has no fire-resistant barriers. The legislation allows buildings of this kind to be constructed, but compensatory measures must be taken to ensure an equivalent level of safety, and approval must be obtained from the Federal Public Service Home Affairs (derogation application) and the fire brigade. The concept therefore had to be finalised down to the smallest detail before construction could begin. “We developed, manufactured and installed a glazed roof structure measuring 110 metres long and 6 metres wide, fitted with 36 transparent Ventria ventilation windows that naturally exhaust both smoke and hot air. We also integrated glazed smoke curtains,” explains Van Cannegem. “The project received a clean report from the Ghent fire brigade. In the gatehouse, we installed a system that allows the fire brigade to immediately see where the fire is located.” Sales manager Florian Vivé concludes: “This multifaceted project gave us ample opportunity to apply all our expertise. We were involved in the design, engineering and installation, and will also provide servicing and maintenance in the long term.”  

PROJECT DETAILS

Project: Facq centre
Location: Merelbeke
Architect: LAB Architects Boveroux Courtoy, Liège

Question about this story? Ask your question

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeKitchens and bathrooms as architecture
  • SubjectProjects
  • CompanyKingspan Light + Air
Share this article

Follow on ArchiComm Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.