Bathrooms & kitchens

Hygiene and safety: which taps should healthcare facilities use?

Hygiene and safety: which taps should healthcare facilities use?


Combating bacterial growth in water networks is a constant challenge in healthcare facilities and public spaces alike. Infections caused by poor control of water network hygiene can be serious. Installing a mixer tap as close as possible to the point of use is therefore an effective way to tackle the problem.

THE PROBLEM: BACTERIAL GROWTH IN WATER NETWORKS

Of the bacteria that occur naturally, Legionella and Pseudomonas Aeruginosa can cause nosocomial infections (or hospital-acquired infections). These are often fatal for people with weakened immune systems.

In biofilm, Legionella develops at water temperatures between 25°C and 45°C. Outside this range, the bacterium remains dormant or is destroyed. Legionella infection occurs when users inhale aerosols, or tiny droplets of water released from the tap, that contain the bacteria.

Pseudomonas Aeruginosa, by contrast, develops at water temperatures between 4°C and 42°C (with an optimum temperature of 30°C to 37°C). This bacterium needs water and air to multiply. Pseudomonas Aeruginosa is therefore mainly found in locations where all these factors are present: primarily in taps, flexible hoses and the first metre of pipework. Infection occurs through direct contact, via a wound or mucous membrane.

LEGAL REQUIREMENTS FOR PREVENTING HOSPITAL-ACQUIRED INFECTIONS

In 2021, the European Centre for Disease Prevention and Control (ECDC) recorded 3.5 million cases of nosocomial infections among patients in healthcare facilities across Europe. These infections caused 90,000 deaths, including 3,000 in Belgium, highlighting the scale of the problem in water networks.

The Flemish Agency for Care and Health and the Dutch Ministry of Infrastructure and Water Management have tackled the issue by drawing up a management plan based on Best Available Techniques (BAT) for the design and operation of sanitary facilities, as well as requiring the bacteriological quality of the water to be measured. 

See our thematic dossier for more information on the regulations for hydraulic installations in public buildings.

AN EFFECTIVE TECHNICAL SOLUTION TO BACTERIA: MIX THE WATER AS CLOSE AS POSSIBLE TO THE POINT OF USE

Preventing bacterial growth requires two measures: minimising stagnant water in the water network and ensuring that hot water remains above 55°C (Belgium) or 60°C (the Netherlands) at every point in the installation.

With a branch connection from the hot water network, water in the pipework is replenished only as far as the sanitary fittings when they are in use. If they are not used regularly, water stagnates in the pipe and cools to a temperature conducive to bacterial growth. This applies to facilities that experience periods of low occupancy (hospitals, seasonal tourism, etc.). Regulations for public buildings therefore prohibit more than 3 litres (Belgium) or 1 litre (the Netherlands) of mixed water between the hot water circulation loop and the point of use.

Mixing the water as close as possible to the point of use brings the hot water circulation pipe close to the sanitary fittings. This ensures that water circulates at a high temperature, preventing the growth of micro-organisms. Once established in the pipework, bacterial colonies are difficult to remove, so prevention at the design stage is a worthwhile strategy.

It is also essential to flush taps regularly to refresh the water and maintain a high level of hygiene in the network. That is why all DELABIE electronic taps are equipped with an automatic periodic flush, which takes place every 24 hours after the last use.

HEALTHCARE FACILITIES: TAILORED SOLUTIONS

DELABIE's range for healthcare facilities, including hospitals, care homes and clinics, comprises washbasin and shower mixer taps that hold little stagnant water in the tap body and protect users from scalding.

Thermal disinfection is simple to carry out: easily release the maximum temperature stop (without removing the control knob or shutting off the cold water supply) to circulate water at 70°C for half an hour. This remedial treatment must be carried out in the event of bacterial contamination of the network.

Many DELABIE solutions meet the requirements of the NF M standard*.

THREE ICONIC MIXER TAPS IN FOCUS:

CERTIFIED, SAFE DUAL-CONTROL SHOWER MIXER TAP

Certified to NF M in July 2021, the H9768BEL thermostatic shower mixer tap holds a very small volume of water in the body and is also fitted with anti-scalding protection. Its thermostatic cartridge ensures a stable temperature despite fluctuations in network pressure and flow rate.

Hot water is limited to 43°C and is shut off automatically and immediately if the cold water supply is interrupted. The tap also features Securitouch technology: its body stays cool, whatever the temperature of the water inside. This eliminates the risk of burns.



WASHBASIN MIXER TAP WITHOUT A SPOUT

The 2621EP washbasin mixer tap has no spout, which limits the volume of water held in the tap body. This mixer tap also features a “thermal disinfection” function and meets the specific requirements of healthcare facilities.

The tap is also fitted with a pressure-compensating cartridge that neutralises unavoidable fluctuations in network pressure. This keeps the water temperature at the point of use perfectly stable and prevents scalding.



« ALL-IN-ONE » MINI THERMOSTATIC MIXING VALVE

The PREMIX NANO (ref. 732216), developed for public spaces, is a very compact thermostatic mixing valve that perfectly meets the needs of healthcare facilities.

Hospitals and care homes are usually fitted with mechanical mixer taps. When taps are used simultaneously (toilet flushing, showers, washbasins, etc.), the cold water pressure can suddenly fluctuate. Installed upstream of the taps, the PREMIX NANO guarantees a stable temperature and protection against scalding at all times.

It can supply two washbasins or one shower, whatever the configuration. It can be used anywhere, in both new-build and refurbishment projects.

* NF 077 MM is a specific standard for taps used in the medical sector, in force since 2017.

A business enquiry for Delabie? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectBathrooms & kitchens
  • CompanyDelabie
Share this article

Follow on ArchiComm Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.